Stay ahead in the carbon-regulated economy with accurate and reliable solutions tailored to your needs.
Our Model’s Measurements
Measurement Object
Method
Flue gas
Full heat tracing methodor
NDIR + GFC wavelength filter + L-Cell Long range filter
NO2
Ultraviolet-visible Differential Optical Absorption Spectroscopy (DOAS)
or
NDIR + GFC wavelength filter + L-Cell Long range filter
CO2
NDIR + GFC wavelength filter + L-Cell Long range filter
SO2
NDIR + GFC wavelength filter + L-Cell Long range filter
Flow Rate
Pitot tube method or matric method
Pressure
Isolation Diaphragm pressure transducer
Temperature
Platinum resistance temperature sensor
PFCs
Depending on density
Specifications and Conditions
System Parameter
Unit
Value
Measuring Range
PPM
0-1000ppm
Lowest measuring limit
ppb
< 250 ppb
Reaction time
second
<60 seconds
Accuracy of Full Scale
%
<1% full scale
The Artem CEMS Module shall run safely for a long time in the harsh environment under the following conditions:
Voltage of power supply
220 (± 10%) V AC/(50 ~ 60) Hz
Measuring Range
(5 ~ 40) °C
Lowest measuring limit
(-30 ~ 60) °C
Reaction time
(86 ~ 106) kPa
Sampling environment temperature: up to 800 ℃ The system is designed with protection against dust, rain, electromagnetic radiation, lightning, low temperature, and fire.